The Master Science Thermo Shaker Dry Bath heats and shakes samples at the same time, combining a PID-controlled block heater with a brushless DC orbital mixer (2 mm orbit, 200 to 3000 rpm). It is used for incubation, enzyme reactions and deactivation, catalysis, mixing and short-term holding of samples.
An independently controlled heated lid up to 110 °C prevents condensation and evaporation on tube caps, and a built-in fan shortens cooling time after a run. Interchangeable blocks fit PCR plates and 0.5 to 2 mL tubes.
Technical Specifications
Specifications of the Master Science Thermo Shaker Dry Bath:
- Brand: Master Science
- Model Number: MSDBI-R3000SWISS
- SKU: MSDBI-R3000SWISS
- Brand: Master Science
- Model Number: MSDBI-R3000SWISS
- SKU: MSDBI-R3000SWISS
- Temperature Setting: 0 to 105 °C
- Temperature Control: RT +5 °C to 105 °C
- Accuracy / Uniformity: ≤ ±0.3 °C / ≤ ±0.3 °C
- Display Resolution: 0.1 °C
- Heating Time: ≤ 10 min (25 to 100 °C)
- Fan Cooling: ≤ 12 min (100 to 37 °C)
- Speed Range: 200 to 3000 rpm, 2 mm orbit
- Motor: Brushless DC
- Heated Lid: OFF/AUTO/40 to 110 °C, independent control
- Timer: 1 s to 99 min 59 s; 1 min to 99 h 59 min; continuous
- Programs: 10 (S0 to S9), up to 5 steps, up to 99 cycles
- Other Functions: Auto preheat, short mix, delay timer, power-failure restart, calibration, over-heat protection
- Power: 335 W
- Power Supply: AC 220 V or 110 V, 50/60 Hz
- Dimensions (L × W × H): 296 × 212 × 164 mm
- Net / Gross Weight: 6.9 kg / 8 kg
Key Benefits
- Heat and mix together: the Master Science Thermo Shaker Dry Bath replaces a separate heater and mixer.
- No condensation on caps: independent heated lid.
- Quicker turnaround: fan-assisted cooling.
- Multi-step methods: 10 programs with up to 5 steps.
- Quiet and durable: brushless DC drive.
For plasma gel syringes, see the Master Science plasma gel maker.
Product Features
Temperature
- PID control to 105 °C
- Heated lid to 110 °C
- Fan cooling
Mixing
- 200 to 3000 rpm
- 2 mm orbit
- Short mix function
Programs and Safety
- 10 programs, 99 cycles
- Power-failure recovery
- Over-heat protection
Applications
The Master Science Thermo Shaker Dry Bath is used for:
- Enzyme reactions and deactivation
- PCR sample preparation
- Sample incubation and mixing
- Holding enzymes or DNA libraries at the bench
- Heating samples in the field
Optional Accessories
- Block for 96 × 0.2 mL PCR plate
- Block for 54 × 0.5 mL tubes
- Block for 35 × 1.5 mL tubes
- Block for 35 × 2.0 mL tubes
- Block for 20 × 1.5 mL + 15 × 0.5 mL
- Custom blocks on request
Common Laboratory Problems and How This Thermo Shaker Helps
How the Master Science Thermo Shaker Dry Bath improves incubations:
- Evaporation from small volumes: heated lid.
- Uneven mixing during incubation: continuous orbital shaking.
- Slow cool-down between runs: built-in fan.
- Runs lost after power cuts: automatic resume.