Atomic Absorption Spectrophotometer - AAS Analyzer - 190-900 nm - 3000°C Graphite Furnace

Model / SKU MSSP-IAA4530SWISS

Inhouse product


Share

The Master Science Atomic Absorption Spectrophotometer is a PC-controlled AAS for measuring metals in solution by flame absorption and flame emission. A floating optical platform protects the light path from vibration, and the software handles lamp selection, burner position, slit, gas flow, ignition and wavelength peak searching automatically.

An eight-lamp turret preheats all hollow cathode lamps at once, so sequences across several elements run without waiting, and an optional graphite furnace extends detection to very low concentrations.

Technical Specifications

Key specifications of the Master Science Atomic Absorption Spectrophotometer and its flame and graphite furnace systems:

  • Brand: Master Science
  • Model Number: MSSP-IAA4530SWISS
  • SKU: MSSP-IAA4530SWISS
  • Atomization: Flame (graphite furnace optional)
  • Wavelength Range: 190 to 900 nm
  • Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength Accuracy: ±0.15 nm
  • Wavelength Repeatability: ≤ 0.04 nm
  • Baseline Stability: ≤ 0.002 A/30 min (Cu)
  • Characteristic Concentration: 0.02 µg/mL/1% (Cu)
  • Detection Limit: 0.004 µg/mL (Cu)
  • Precision: 0.5 %
  • Grating: 1800 lines/mm
  • Burner: All-metal titanium burner, 100 mm air-acetylene
  • Nebulizer: High-efficiency glass nebulizer
  • Lamp Positions: 8, automatic switching and preheating
  • Background Correction: Deuterium lamp and self-absorption; ≥ 50× at 1 A background
  • Flame Dynamic Baseline Drift: ≤ 0.006 A/30 min
  • Flame RSD: ≤ 0.5 % (Cu, absorbance > 0.8 A)
  • Graphite Furnace Max Temperature: 3000 °C
  • Graphite Furnace Heating Rate: ≥ 2000 °C/s
  • Graphite Furnace Characteristic Mass: Cd ≤ 0.5 × 10⁻¹² g; Cu ≤ 0.5 × 10⁻¹¹ g
  • Graphite Furnace Precision: Cu ≤ 3 %, Cd ≤ 3 %
  • Graphite Furnace Power: 220 V ±22 V AC, 7000 W
  • Graphite Furnace Size / Weight: 730 × 625 × 700 mm, 79.3 kg
  • Main Unit Power: 220 V ±22 V AC
  • Package Size: 840 × 700 × 780 mm (main unit); 1170 × 645 × 900 mm (accessories)

Key Benefits

  • Safer flame operation: the system shuts off gas automatically on power loss, abnormal flame, low pressure or wrong burner.
  • Faster multi-element runs: eight lamps are preheated together and switched automatically.
  • Steady optical signal: the Master Science Atomic Absorption Spectrophotometer uses a floating optical platform that resists shock and drift.
  • Accurate furnace heating: PID control and 3 ms sampling overcome voltage and resistance changes during the temperature program.
  • Standard mains power: the graphite furnace runs on ordinary 220 V supply, with no 380 V line required.

Laboratories that also measure organic contaminants often pair AAS with the Master Science gas chromatograph.

Product Features

Full Software Control

  • Element lamp selection and energy adjustment
  • Burner height and front-rear positioning
  • Slit selection and automatic wavelength peak search
  • Gas flow control with automatic ignition and flame-out
  • Graphite furnace method setup

Flame System

  • Electronic flow control of acetylene
  • Efficient nebulization for higher sensitivity
  • Complete safety interlock chain

Graphite Furnace

  • PID temperature control with fast sampling
  • Up to 20 heating steps
  • Three-level adjustable inert gas flow
  • Alarms for gas or cooling water failure

Data Handling

  • Storage of more than 500 results with power-off protection
  • Excel export and method recall
  • Parameter, result and graph printing

Applications

The Master Science Atomic Absorption Spectrophotometer is used for metal analysis in:

  • Environmental water, soil and sediment testing
  • Food and agricultural products
  • Pharmaceutical and cosmetic raw materials
  • Metallurgy, mining and geology
  • Clinical and public health laboratories

Standard Accessories Included

  • PC workstation
  • Inkjet printer
  • Oil-free air compressor
  • Acetylene pressure-reducing valve
  • Cu hollow cathode lamp
  • Air filter

Optional Accessories

  • Additional hollow cathode lamps
  • Graphite tubes
  • Recirculating cooling water system
  • Hydride generator

Common Laboratory Problems and How This AAS Helps

How the Master Science Atomic Absorption Spectrophotometer helps with common metal analysis issues:

  • Waiting for lamps to warm up: all eight lamps preheat together.
  • Operator safety with acetylene: automatic gas shut-off reacts to any abnormal condition.
  • Signal drift over long runs: the floating optical platform keeps the light path stable.
  • Insufficient sensitivity for trace levels: the optional graphite furnace reaches picogram-level detection.
  • Manual record keeping: results export to Excel and print directly.

Frequently Bought Products

"Master Science - Leading Provider of Laboratory Equipment & Analytical Instruments"

"Explore Master Science, your trusted provider of high-quality laboratory equipment and innovative solutions. Discover our extensive range of analytical instruments and exceptional customer support, all dedicated to empowering scientific discovery across industries. Join us in advancing research and setting new standards globally."